#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

The solution of persistent stress urinary incontinence in women when surgery with the TVT-SECUR* is unsuccessful


Authors: A. Martan 1 ;  K. Švabík 1;  J. Mašata 1;  T. Koleška 1;  R. El-Haddad 1;  M. Pavlikova 2
Authors‘ workplace: Gynekologicko-porodnická klinika VFN a 1. LF UK, Praha, přednosta prof. MUDr. A. Martan, DrSc. 1;  EuroMISE Centrum, Ústav informatiky Akademie věd České republiky, v. v. i., ředitelka prof. RNDr. J. Zvárová, DrSc. 2
Published in: Ceska Gynekol 2009; 74(1): 3-7

Overview

Objective:
The objective of this study is to evaluate the efficacy of the procedure of shortening the tape in the treatment of persistent stress urinary incontinence when the tension-free vaginal tape (TVT) SECUR procedure proves unsuccessful.

Design:
Retrospective study.

Settings:
Department of Gynecology and Obstetrics, First Faculty of Medicine, Charles University and General Teaching Hospital, Prague.

Materials and methods:
Eight patients with persistent stress urinary incontinence (SUI) after the TVT-S procedure were included in our study. In order to resolve their condition, the tape was shortened. We used the overlap and the cut-off technique. Pre- and postoperative urodynamic and ultrasound (US) examinations were carried out, and the efficacy of this procedure was evaluated by cough test, pad-weighting test (PWT) and by the questionnaires Pelvic Organ Prolapse/ Urinary Incontinence Sexual Function Questionnaire (PISQ12) and the International Consultation on Incontinence Questionnaire – Short form (ICIQ - UI SF). All data were processed and statistical analyses performed in statistical environment R, version 2.5.1.

Results:
In six patients the cough test and PWT were negative after reoperation, indicating no stress urinary incontinence, while in two patients mild leakage of urine persisted. The reoperation significantly increased the value of Maximum Urethral Closure Pressure (MUCP) while coughing. From the US examination we can conclude that the tape is tightened closer to the urethra and pubic bone.

Conclusions:
We describe a method - shortening the tape - for the treatment of persistent stress urinary incontinence when the TVT–S procedure fails. Based on our results we have established that this procedure is simple and as effective as inserting a new tape, but cheaper.

Key words:
urinary incontinence in women, complications, TVT-S, transperineal ultrasound examinations.


Sources

1. Ulmsten, U., Falconer, C., Johnson P., et al. A multicenter study of tension-free vaginal tape (TVT) for surgical treatment of stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct, 1998, 9, p. 210-213.

2. Ulmsten, U., Petros, P. Intravaginal slingplasty (IVS): an ambulatory procedure for treatment of female urinary incontinence. Scand J Urol Nephrol, 1995, 29, p. 75-82.

3. Delorme, E. Trans-obturator urethral suspension: mini-invasive procedure in the treatment of stress urinary incontinence in women. Prog Urol, 2001, 11, p. 1306-1313.

4. Delorme, E., Droupy, S., de Tayrac, R., et al. Transobturator tape (Uratape): a new minimally–invasive procedure to treat female urinary incontinence. Eur Urol, 2004, 45, p. 203-207.

5. DeLeval, J. Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out. Eur Urol, 2003, 44, p. 724-730.

6. Collinet, P., Ciofu, C., Costa, P., et al. The safety of the inside-out transobturator approach for transvaginal tape (TVT-O) treatment in stress urinary incontinence: French registry data on 984 women. Int Urogynecol J Pelvic Floor Dysfunct, 2008, 19, p. 711-715.

7. Charalambous, S., Touloupidis, S., Fatles, G., et al. Transvaginal vs transobturator approach for synthetic sling placement in patients with stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct, 2008, 19, p. 357-60.

8. Mellier, G., Benayed, B., Bretones, S., et al. Suburethral tape via the obturator route: is the TOT a simplification of the TVT? Int. Urogynecol J Pelvic Floor Dysfunct, 2004, 15, p. 227-232.

9. Paick, JS., Oh, JG., Shin, JW., et al. Significance of tension in tension-free mid-urethral sling procedures: a preliminary study. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 153-158.

10. Vervest, HAM., Bisseling, TM., Heintz, APM., et al. The prevalence of voiding difficulty after TVT, its impact on quality of life, and related risk factors. Int Urogynecol J Pelvic Floor Dysfunct, 2006, 18, p. 173-182.

11. Boyles, SH., Edwards, R., Gregory, W., et al. Complications associated with transobturator sling procedures. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 19-22.

12. Stanton, SL. Mid-urethral tapes: Which? Review of available commercial mid-urethral tapes for the correction of stress incontinence. BJOG, 2004, 111, p. 41-45.

13. Game, X., Mouzin, M., Vaessen, C., et al. Obturator infected hematoma and urethral erosion following transobturator tape implantation. J Urol, 2004, 171, p. 1629.

14. Richards, SR., Balaloski, SP. Vulvar hematoma following a transobturator sling (TVT-O). Int Urogynecol J Pelvic Floor Dysfunct, 2006, 17, p. 672-673.

15. Novara, G., Galfano, A., Boscolo-Berto, R., et al. Complication rates of tension-free midurethral slings in the treatment of female stress urinary incontinence: A systematic review and meta-analysis of randomized controlled trials comparing tension – free midurethral tapes to other surgical procedures and different devices. Eur Urol, 2008, 53, p. 288-308.

16. Rezapour, M., Novara, G., Meier, PA., et al. A 3-month preclinical trial to assess the performance of a new TVT-like mesh (TVTx) in a sheep model. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 173-182.

17. Martan, A., Mašata, J., Petri, E., et al. Weak VLPP and MUCP correlation and theier relationship with objective and subjective measures of severity of urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 267-271.

18. Jakobsen, H., Veden, P., Anderson, JT. Objective assessment of urinary incontinence: an evaluation of three different pad-weighing test. Neurourol Urodyn, 1987, 6, p. 325-330.

19. Schaefer, W., Abrams, P., Liao, L., at al. Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure-flow studies. Neurourol Urodyn, 2002, 21, p. 261-274.

20. Lose, G., Grifiths, DJ., Hosker, G., et al. Standardisation of urethral pressure measurement: Report of the sub-committee of the International Continence Society. Neurourol Urodyn, 2002, 21, p.258-260.

21. Marsh, FA., Assassa, P. An audit of the introduction of TVT Secur in clinical practice. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 26.

22. Neuman, M. Trans vaginal tape readjustment after unsuccessful tension-free vaginal tape operation. Neurourol Urodyn, 2004, 23, p. 282-283.

23. Moore, RD., Gamble, K., Miklos, JR. Tension-free vaginal tape sling for recurrent stress incontinence after transobturator tape sling failure. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18, p. 309-313.

24. Paick, JS., Ku, JH., Shin, JW., et al. Shortening of tension –free vaginal tape for the treatment of recurrent incontinence. J Urol, 2004, 171, p..1634.

25. Kobashi, KC., Govier, FE. Management of vaginal erosion of polypropylene mesh slings. J Urol, 2003, 169, p..2242-2243.